Hands-on tutorial

Tutorials · Switching

How to Build an Out-of-Band Management Network

Keep access to switches, gateways and servers when the main network is down: a separate management network, console servers, 4G backup access and strict security.

Advanced10 min6 steps

Before you start

  • A list of critical devices with management or console ports
  • A small management switch per rack or site
  • A secure remote access method for the management network

Step by step

  1. Separate management from production

    Connect dedicated management ports (or a management VLAN on separate hardware) to a management switch that does not depend on the production core.

  2. Add console servers

    A console server connects to the serial console of each critical device, so you can recover even if the device has no network configuration.

  3. Give it its own path

    Connect the management network to the outside through a separate internet link or a 4G/5G router, so you can reach it during a full outage.

  4. Secure access tightly

    Access only through VPN with MFA, from named administrator accounts, with logging. Never expose console servers to the internet.

  5. Power it independently

    Put the management switch, console server and 4G router on UPS power.

  6. Test it

    Disconnect the production uplink in a maintenance window and confirm you can still reach every critical device.

Pro tips

  • Label console cables and ports clearly.
  • Keep management IP plans separate from production.
  • Use the management network for backups and monitoring traffic too.